ultrasonic support dissolve



















When I was having hands printed on the Stratasys Fortus at Innovation Accelerator I noticed the bottle of Stratasys solution that was near the wash station. I noted that the "special Stratasys solution" contained sodium hydroxide. This is the same caustic solution that we utilize for a cleaning solution when anodizing aluminum so I happen to have a few bottles of the necessary material. Jerry had given me a few parts that were still loaded with support so I decided to see if I could dissolve it with my sodium hydroxide and one of my ultrasonic cleaners in my studio. I am happy to report that this worked like a charm. The ultrasonic has a heater so it keeps the solution warm and the ultrasonic action seems to speed the process; just like when I clean investment from castings. The ultrasonic cleaner also has a stainless steel liner, so that should keep it from etching through the metal (as it would with an aluminum pan-ask me how I know this). I left the parts in the solution over night and came back to clean parts with no support. The parts just require a rinse after they are pulled out and then I scrub them just to remove traces of the solution. There were no remnants of support material left when the parts were pulled from the solution. I have been reading more on the topic and it appears that the solution should dissolve PLA also. I'll run some tests though and report my findings. Also, it might be nice to check out the cheap Harbor Freight ultrasonic cleaners to see how they hold up to the job.











Saturday, March 14, 2015

coex mg94/fdm 2000




I have the FDM 2000 up and running again. I ordered some Coex MG94 filament and I am absolutely loving it. I ran a calibration cube today and then sliced a Raptor gauntlet to print. I still need to do a little calibration, but things are looking pretty good.





Friday, June 13, 2014

stratasys fdm 2000: start-up





While I was robbing parts from the Prodigy, I grabbed a new/old light for the FDM 2000. Yes, they're the same as well. I got everything back together and then fired it up so I could start heating the extruders and the build envelop. I was worried that after sitting for so long, that everything would be clogged up, but loading some new support material that Have Blue had spooled for me proved to be routine. I did notice however that the rollers on the model side look like they are out of alignment. This would explain my earlier kinking problems right as the filament goes into the liquefier inlet. I didn't have a torx head in the studio that would fit the roller, so I'll have to bring one in. I'm feeling really good about this rebuild though. I just need to order up some good filament and I'll be back in business with the FDM 2000.







stratasys fdm 2000: blower replacement




























You will notice that the FDM 2000 has some kind of heat exchanger on each side of the machine. These are mounted to a metal enclosure that ducts the air that is sucked from the bottom of the build chamber up over the exchanger and into the top portion of the the build area where the extruder build each layer of a print. The left side of the machine also has what appears to be a temp sensor that is bolted through the build chamber. Stratasys designed the build chamber with the same aluminum side plates though as there is a hole for the sensor on the right side and a hole for the clip that keeps it's wire from coming in contact with the heat exchanger. There is also a plug present on the right side plate that is not on the left, but there is still a mounting hole for it at the rear on the left side plate. 

After I detached the blowers from the side duct on the left side, I was able to confirm that they we're indeed toasted. Have Blue had given me a couple of NOS blowers that he had in a stash of Stratasys parts, but one of them was not a match for my two dissenigrated blowers. I looked up the specs for the blowers and was able to find some on ebay, but then I remembers that I had a gutted Stratasys Prodigy Plus setting in the DCRL. There couldn't be a chance that they used the same blower. Sure enough they did! The blowers had shorter wires and a plug on the Prodigy version but the specs were the same. Bingo, I have blowers and the FDM 2000 is back in business.  I transferred the old gasket material to the new/old blowers and then everything could be bolted back together. Before I did this, I cleaned the heat exchangers on both sides as there was filament that had gotten down inside. No wonder the machine would smell so bad once it was heated up. I just vacuumed everything out and made sure all of the foam dust was gone as well. I bolted everything back together and connected the blower wires and then tuned on the cdm 2000 to see if we had air. Sure enough; it was good to go. Time to put all the covers back on...









stratasys fdm 2000: electronics closer look























Here is a closer look of the electronics that are controlling the FDM 2000. Everything  shown here is located at the top of the machine under the top hood. Check out the joystick port for jogging the machine around.